Global Serivce Tel: (+86) 186-8200-5391 Spanish&Russia Website http://www.hexcellchina.com/
Global Serivce Tel: (+86) 186-8200-5391 Spanish&Russia Website http://www.hexcellchina.com/
Single Phase BS Type Electronic Energy Meter is designed and manufactured using today's advanced electric energy meter specific integrated circuits, microprocessors, high-stability memory for permanently storing information, wide-temperature liquid crystal display technology, and SMT process. High precision, wide load, high sensitivity and low power consumption for AC active energy measurement in single-phase power grids with rated frequency of 60Hz. This table integrates many functions into one, realizes active energy metering, and can be used flexibly to select various presets. Function: Power, fault alarm, infrared meter reading and other functions. The PC and PDA are used as the media to realize the information transmission between the users and the power supply department computers. It has an infrared interface to facilitate the power department to implement computer network management. And use a variety of software, hardware anti-jamming measures to ensure the reliable operation of the meter, so as to adapt to the power department's effective and timely modern scientific management needs.
The performance indicators meet the technical requirements of the standard IEC62052-11 and IEC62053-21 for single-phase electronic energy meters.
1.1 Features
1.1.1 LCD display: meter displays current energy consumption when power off.
1.1.2 Wide operation voltage between 0.7Un~1.15Un.
1.1.3 The linear error is small in a large load range, and there is no need to calibrate;
1.1.4 With optical port;
1.1.5 Active pulse indicator for pulse output test;
1.1.6 Measure forward &reverse active energy;
1.1.7 Measure and display voltage, current, instantaneous demand;
1.2 Working Principle
The working principle of the meter is shown in the figure below:
When meter is under working, the
voltage and current are sampled by the sampling circuit and then multiplied by
the energy processing unit in the SOC chip and sent to the CPU unit in the SOC
chip for processing. Finally, the CPU unit in the SOC chip sends the processed
data to display parts, communication parts and other output devices according
to the needs.
Each performance index meets the technical requirements of standard IEC62052-11 and IEC62053-21 for single-phase electronic energy meters.
2.1 Specification and Parameters
2.1.1 Voltage and current
Rated operation voltage:
1P2W: Un is 120V, working voltage range(70%~115%)Un;
1P3W: Un is 240V, working voltage range(70%~115%)Un;
Rated Current:
1P2W: 15 (100) A;
1P3W: 15(100)A;
Single-phase critical voltage: meter can work over 70% of Un (normal measurement and communication over 0.7Un).
Voltage circuit: <1W or 10VA
Current circuit: <4VA
2.1.2 Accuracy: Class 1 .0
2. 1. 3Starting Current: ≤0.004Ib
2. 1.4 No-load: with logic anti no-load function
2. 1.5 Pulse constant:
1P2W: 3200imp/kWh
1P3W: 1600imp/kWh
2. 1.6 kWh LCD: Display 0~999999kWh.
2. 1.7 Working temperature range:
Normal working temperature: -25℃~+60℃
Limit working temperature: -30℃~+70℃
Storage and transportation temperature: -40℃~+70℃
30 days a year (natural diffusion) Humidity up to 95% and sometimes up to 85% for the rest of the year
2. 1.8 Net weight:
1P2W: 0.491kg(0.546kg with internal carton box)
1P3W: 0.554kg(0. 607kg with internal carton box)
2. 1.9 Battery: 3.6VDC 1.2Ah; Non-rechargeable green battery.
3.1 LCD display screen
3.2
Pulse LED
On the bottom of the LCD display, there is a long-life LED
light-emitting diode as a pulse indicator: it is always off, and flashes when
the active energy is measured.
3.3 Display content
3.3.1 English LCD display.
3.3.2 LCD alarm indicators
3.3.3 With automatic cycle display, key cycle display in two ways
In the automatic cycle display, the interval of each display cycle display can be set within 5 to 20 seconds.
3.3.4 LCD display when power off
3.3.5 kWh value display digit: 6 integers
4.1.1 Measurement
Active energy measurement: forward measurement, forward measurement even when current is reverse, accumulated forward and reverse energy and store these data.
4.1.2 Display
4.1.2.1 Large-screen, wide-temperature digital and English characters LCD display with UV protection function. Under normal use conditions, LCD life is more than 10 years.
4.1.3 Communication function
With an infrared communication interface, the transmission rate is set to
1200bps by half-duplex. Energy meter can communicate with handheld terminals,
data collectors, detection devices, computers, etc. through the communication
interface for data transmission, broadcast time setting, reading, programming,
management, and etc.
4.1.4 Pulse output
Energy meter has LED pulse and electric pulse output function proportional to the measured energy consumption.
4.1.5 Status indicator
In the bottom of the
LCD display, there is a LED light-emitting diode, which is defined as a pulse
indicator: it is always off, and flashes when the active energy is measured.
5.1 Outline and installation dimension:
5.2 Wiring diagram
1P2W:
1P3W:
5.3 Pulse output diagram
6.1 The transport and unpacking of the electric energy meter should not be subject to severe impact and should be transported and stored in accordance with regulations.
6.2 The electric energy meter should be stored in the original packaging, where the ambient temperature is -30°C~+70°C, and the relative humidity is no more than 85%. There is no corrosive gas in the air.
6.3 Energy meter is stored in the warehouse and should be placed on a gantry with a stack height of no more than 6 boxes. After unpacking, the stacking height of the single-packed power meters shall not exceed 6pcs.